Fan coil units
Double skin fan coil units for ducted applications, engineered for Australia and New Zealand and backed by our local engineering team.

Built for Australian and New Zealand projects
Our double skin fan coil units cover nominal airflows from 150 to 2,280 L/s, with chilled water cooling up to 47 kW from a single unit. Selected models are held in stock for fast programmes.
They are designed around Australian hygiene and energy requirements, with drain trays to AS/NZS 3666 and coil selections checked against NCC Section J.
Send us your schedule and our engineers will return full selections with technical data.
Our fan coil units
View the range for performance data and dimensions.

- Injected PU double-skin casing, 25 or 50 mm
- High static EC plug fans, 0–10 V control
- Stainless drain trays to AS/NZS 3666.1
- Revit families for all nine models
Need a cassette, wall-mounted or low-noise unit? Talk to our team about other fan coil options for your project.
Talk to our teamThe range
| Model | Rated airflow (L/s) | Max airflow (L/s) | EC fans | W × D × H (mm) | Cooling (kW) | Heating (kW) |
|---|---|---|---|---|---|---|
| EFU-030 | 150–250 | 320 | 1 | 700 × 800 × 450 | 2.8–5.9 | 3.5–9.0 |
| EFU-038 | 200–300 | 390 | 1 | 800 × 800 × 450 | 3.7–7.3 | 4.2–10.4 |
| EFU-053 | 300–500 | 562 | 1 | 1,050 × 800 × 450 | 5.4–11.6 | 6.8–17.1 |
| EFU-075 | 450–650 | 772 | 2 | 1,350 × 800 × 450 | 8.2–15.3 | 10.3–23.4 |
| EFU-110 | 650–1,000 | 1,163 | 2 | 1,650 × 800 × 500 | 11.8–24.3 | 15.7–36.0 |
| EFU-130 | 800–1,200 | 1,410 | 2 | 1,950 × 800 × 500 | 14.8–28.6 | 20.4–43.9 |
| EFU-150 | 900–1,400 | 1,625 | 3 | 1,950 × 800 × 550 | 16.7–32.2 | 22.9–48.6 |
| EFU-170 | 1,000–1,600 | 1,843 | 3 | 1,950 × 800 × 600 | 18.8–37.7 | 26.1–58.6 |
| EFU-210 | 1,200–2,000 | 2,278 | 4 | 1,950 × 800 × 700 | 22.8–47.1 | 31.6–68.2 |
Inside the unit
Every model is built from the same components, so performance, access and spares are consistent across the range.

- 50 mm G4 panel filter
- PTC heater
- UV-C steriliser light
- Valve kit
- Filter plenum
- Disconnect switch
- Galvanised steel inner and outer skins, 0.5 mm each
- 25 or 50 mm injected polyurethane
- No insulation exposed to the airstream
- Seamless copper tubes, aluminium fins
- Cooling: 3, 4 or 6 rows
- Heating: 1 or 2 rows
- Pressure tested to 2 MPa
- Direct-drive EC plug fans
- Integrated 0–10 V speed control
- 230 V / 1 ph / 50 Hz
- Stainless steel to AS/NZS 3666.1
- Extends beneath both coils
- Chilled water: 32 mm welded pipe
- Heating water: 25 mm welded pipe
- Drain: 25 mm BSP male
- Left or right hand



Key projects
Colair fan coil units are installed in commercial, sporting and residential projects across Australia.




Talk to our fan coil teamSend us your fan coil schedule and our engineers will recommend the right unit, with technical data and drawings. |
|